Sri Praveen S.P,
Sr. Divisional Signal & Telecom Engineer
Phone Rly: 46400, Mobile No. 9731668800
Signal & Telecom infrastructures
Signalling:
|
Sl. No. |
Description |
Qty |
|
1. |
Total No. of stations/IBS |
138 stations |
|
Electronic Interlocking with MACLS |
100 |
|
|
Panel interlocking with Route Setting type (MACLS) |
11 |
|
|
Panel interlocking with MACLS |
20 |
|
|
“C” Class stations |
06 |
|
|
2. |
Standard of interlocking |
|
|
“B” Class Standard – II (R) |
119 |
|
|
“B” Class Standard – I (R) |
09 |
|
|
“A” Class Standard – I (R) |
03 |
|
|
“C” Class Standard – II (R) |
06 |
|
|
3. |
Total No. of Block Sections (115 Nos) |
Single line: 39 Double line: 86 Tablet token: 01 |
|
4. |
Block Proving Axle counter Sections |
125 Nos |
|
5. |
Total number of interlocked traffic LC gates |
83 LC gates |
|
6. |
Total number of interlocked Mid-section LC gates |
59 LC gates |
|
7. |
Provision of Sliding boom for interlocked LC gates in addition to Mechanically operated / Electrically operated LC gates |
83 Traffic LC gates 57 Mid-section LC gates |
|
8. |
Total No. of LED aspects |
9223 nos |
|
9. |
Total No. of point machines: |
143mm stock: 1507 220mm stock: 792 |
|
10. |
Total No. of track circuits |
3781 |
|
11. |
Integrated Power Supply System (IPS) provided at stations |
137 |
Telecommunication:
|
Sl. No. |
Description |
Qty |
|
1. |
Optical Fibre Cable |
1416 kms |
|
2. |
6 Quad cable |
1416 kms |
|
3. |
Coach guidance display systems |
15 Stations |
|
4. |
Train Display systems |
14 Stations |
|
5. |
Video Surveillance systems |
07 Stations |
|
6. |
Public Announcement system |
96 Stations |
|
7. |
GPS Clock at Stations |
97 Stations |
|
8. |
VHF sets (25W) |
147 Stations |
|
9. |
Telephone exchange |
14 locations |
|
10. |
FOIS |
51 locations |
|
11. |
PRS / UTS |
115 locations |
|
12. |
Railnet users |
4000 Nos |
|
13 |
Wi-Fi |
113 Stations |

Accessibility Controls